Search Catalog
        
 Flowmeters for Industrial Applications    G2 PVDF Chemical Industrial Flowmeters
Flowmeters for Industrial Applications > Turbine Flowmeters - G2 Series Industrial Grade Models > G2 PVDF Chemical Industrial Flowmeters > View Items  

G2 PVDF Chemical Industrial Flowmeters

Check up to five results to perform an action.

Looking for a turbine flowmeter that can handle aggressive chemicals? Use PVDF flowmeters to measure bleach, ferric chloride, phenol, sulfuric acid or phosphoric acid. The lithium battery powered electronic displays are calibrated to read in gallons and liters per minute with two totals in which case one is resettable and gives you a cumulative flow total. These pvdf chemical flowmeters come in ½ in. and 1 in. models.

Watch The G2 Series PVDF Meter video on YouTube.

Watch How To Calibrate an 09 Computer Display on YouTube.

Watch How To Convert your 09 Computer Display from Local to Remote on YouTube.






    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  


 Spares and Accessories: G2 Industrial Flowmeters 


Exploded View G2 Stainless Steel Industrial Meters
Spares: G2 Series Aluminum, Brass and Stainless Steel Meters


Exploded View G2 PVDF Industrial Meters
Spares: G2 Series PVDF Meters

more available ..

   
  Results 1 - 56 of 56 1 

Item #

Inner Diameter

Fitting

Accuracy

Flow Range

Display

Reads

Typical K-Factor

Popularity

ZZ RQ Attribute List Price

G2P05N09GMA ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 Most Popular QUOTE
G2P05N19GMA ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05N43GMC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05N53GMC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05N63GMC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05N73GMC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05N41XXC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
No Display No Calibration 2,400 N/A QUOTE
G2P05N51GMC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - GG500 Transmitter Gallons
Litres
2,400 N/A QUOTE
G2P05N52GMC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - GG500 Transmitter Gallons
Litres
2,400 N/A QUOTE
G2P05N61GMC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - GX500 Transmitter Gallons
Litres
2,400 N/A QUOTE
G2P05N62GMC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - GX500 Transmitter Gallons
Litres
2,400 N/A QUOTE
G2P05N71XXC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
No Display No Calibration 2,400 N/A QUOTE
G2P05N72XXC ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
No Display No Calibration 2,400 N/A QUOTE
G2P05NXXXXA ½ Inch NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
No Display Turbine Only 2,400 N/A QUOTE
G2P05I09LMA ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 Most Popular QUOTE
G2P05I19LMA ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05I43LMC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05I53LMC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05I63LMC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05I73LMC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - 09 Computer Gallons
Litres
2,400 N/A QUOTE
G2P05I41XXC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
No Display No Calibration 2,400 N/A QUOTE
G2P05I51LMC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - GG500 Transmitter Gallons
Litres
2,400 N/A QUOTE
G2P05I52LMC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - GG500 Transmitter Gallons
Litres
2,400 N/A QUOTE
G2P05I61LMC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - GX500 Transmitter Gallons
Litres
2,400 N/A QUOTE
G2P05I62LMC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
LCD - GX500 Transmitter Gallons
Litres
2,400 N/A QUOTE
G2P05I71XXC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
No Display No Calibration 2,400 N/A QUOTE
G2P05I72XXC ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
No Display No Calibration 2,400 N/A QUOTE
G2P05IXXXXA ½ Inch ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1.2 to 12 GPM
4.54 to 45.42
LPM
No Display Turbine Only 2,400 N/A QUOTE
G2P10N09GMA 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 Most Popular QUOTE
G2P10N19GMA 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10N43GMC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10N53GMC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10N63GMC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10N73GMC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10N41XXC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 540 N/A QUOTE
G2P10N51GMC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GG500 Transmitter Gallons
Litres
540 N/A QUOTE
G2P10N52GMC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GG500 Transmitter Gallons
Litres
540 N/A QUOTE
G2P10N61GMC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GX500 Transmitter Gallons
Litres
540 N/A QUOTE
G2P10N62GMC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GX500 Transmitter Gallons
Litres
540 N/A QUOTE
G2P10N71XXC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 540 N/A QUOTE
G2P10N72XXC 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 540 N/A QUOTE
G2P10NXXXXA 1 Inch NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display Turbine Only 540 N/A QUOTE
G2P10I09LMA 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 Most Popular QUOTE
G2P10I19LMA 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10I43LMC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10I53LMC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10I63LMC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10I73LMC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
540 N/A QUOTE
G2P10I41XXC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 540 N/A QUOTE
G2P10I51LMC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GG500 Transmitter Gallons
Litres
540 N/A QUOTE
G2P10I52LMC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GG500 Transmitter Gallons
Litres
540 N/A QUOTE
G2P10I61LMC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GX500 Transmitter Gallons
Litres
540 N/A QUOTE
G2P10I62LMC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GX500 Transmitter Gallons
Litres
540 N/A QUOTE
G2P10I71XXC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 540 N/A QUOTE
G2P10I72XXC 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 540 N/A QUOTE
G2P10IXXXXA 1 Inch ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display Turbine Only 540 N/A QUOTE
  Results 1 - 56 of 56 1