Search Catalog
        
 Flowmeters for Industrial Applications    G2 Stainless Steel Industrial Flowmeters
Flowmeters for Industrial Applications > Turbine Flowmeters - G2 Series Industrial Grade Models > G2 Stainless Steel Industrial Flowmeters > View Items  

G2 Stainless Steel Industrial Flowmeters

Check up to five results to perform an action.

The GPI Stainless Steel Flowmeter line are used with ammonium, plating solutions, caustic and acidic cleaning agents, fuel products and other chemicals. The lithium battery powered electronic display G2 Stainless Steel flowmeters are calibrated to read in gallons and liters per minute with two totals in which case one is resettable and gives you a cumulative flow total. The G2 Stainless Steel flowmeters come in ½ in, ¾  in, 1 in, 1½ in, and 2 inch models.

Watch the G2 Stainless Steel video on YouTube.

Watch How To Calibrate an 09 Computer Display on YouTube.

Watch How To Convert your 09 Computer Display from Local to Remote on YouTube.






    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  


 Spares and Accessories: G2 Industrial Flowmeters 


Exploded View G2 Stainless Steel Industrial Meters
Spares: G2 Series Aluminum, Brass and Stainless Steel Meters


Exploded View G2 PVDF Industrial Meters
Spares: G2 Series PVDF Meters

more available ..

   
  Results 1 - 140 of 140 1 

Item #

Inner Diameter

Fitting

Accuracy

Flow Range

Display

Reads

Typical K-Factor

Popularity

G2S05N09GMA ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 Most Popular
G2S05N19GMA ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05N43GMC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05N53GMC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05N63GMC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05N73GMC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05N41XXC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
No Display No Calibration 2,500 N/A
G2S05N51GMC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - GG500 Transmitter Gallons
Litres
2,500 N/A
G2S05N52GMC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - GG500 Transmitter Gallons
Litres
2,500 N/A
G2S05N61GMC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - GX500 Transmitter Gallons
Litres
2,500 N/A
G2S05N62GMC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - GX500 Transmitter Gallons
Litres
2,500 N/A
G2S05N71XXC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
No Display No Calibration 2,500 N/A
G2S05N72XXC ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
No Display No Calibration 2,500 N/A
G2S05NXXXXA ½ in. NPT
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
No Display Turbine Only 2,500 N/A
G2S05I09LMA ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05I19LMA ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05I43LMC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05I53LMC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05I63LMC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05I73LMC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - 09 Computer Gallons
Litres
2,500 N/A
G2S05I41XXC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
No Display No Calibration 2,500 N/A
G2S05I51LMC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - GG500 Transmitter Gallons
Litres
2,500 N/A
G2S05I52LMC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - GG500 Transmitter Gallons
Litres
2,500 N/A
G2S05I61LMC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - GX500 Transmitter Gallons
Litres
2,500 N/A
G2S05I62LMC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
LCD - GX500 Transmitter Gallons
Litres
2,500 N/A
G2S05I71XXC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
No Display No Calibration 2,500 N/A
G2S05I72XXC ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
No Display No Calibration 2,500 N/A
G2S05IXXXXA ½ in. ISO
½
in.
±1.5 % of reading with Computer
±2.0
% of reading without Computer
1 to 10 GPM
3.8 to 37.9
LPM
No Display Turbine Only 2,500 N/A
G2S07N09GMA ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 Most Popular
G2S07N19GMA ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07N43GMC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07N53GMC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07N63GMC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07N73GMC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07N41XXC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
No Display No Calibration 1,100 N/A
G2S07N51GMC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - GG500 Transmitter Gallons
Litres
1,100 N/A
G2S07N52GMC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - GG500 Transmitter Gallons
Litres
1,100 N/A
G2S07N61GMC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - GX500 Transmitter Gallons
Litres
1,100 N/A
G2S07N62GMC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - GX500 Transmitter Gallons
Litres
1,100 N/A
G2S07N71XXC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
No Display No Calibration 1,100 N/A
G2S07N72XXC ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
No Display No Calibration 1,100 N/A
G2S07NXXXXA ¾ in. NPT
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
No Display Turbine Only 1,100 N/A
G2S07I09LMA ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07I19LMA ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07I43LMC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07I53LMC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07I63LMC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07I73LMC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - 09 Computer Gallons
Litres
1,100 N/A
G2S07I41XXC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
No Display No Calibration 1,100 N/A
G2S07I51LMC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - GG500 Transmitter Gallons
Litres
1,100 N/A
G2S07I52LMC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - GG500 Transmitter Gallons
Litres
1,100 N/A
G2S07I61LMC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - GX500 Transmitter Gallons
Litres
1,100 N/A
G2S07I62LMC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
LCD - GX500 Transmitter Gallons
Litres
1,100 N/A
G2S07I71XXC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
No Display No Calibration 1,100 N/A
G2S07I72XXC ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
No Display No Calibration 1,100 N/A
G2S07IXXXXA ¾ in. ISO
¾
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
2 to 20 GPM
7.6 to 75.7
LPM
No Display Turbine Only 1,100 N/A
G2S10N09GMA 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 Most Popular
G2S10N19GMA 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10N43GMC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10N53GMC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10N63GMC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10N73GMC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10N41XXC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 565 N/A
G2S10N51GMC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GG500 Transmitter Gallons
Litres
565 N/A
G2S10N52GMC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GG500 Transmitter Gallons
Litres
565 N/A
G2S10N61GMC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GX500 Transmitter Gallons
Litres
565 N/A
G2S10N62GMC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GX500 Transmitter Gallons
Litres
565 N/A
G2S10N71XXC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 565 N/A
G2S10N72XXC 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 565 N/A
G2S10NXXXXA 1 in. NPT
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display Turbine Only 565 N/A
G2S10I09LMA 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10I19LMA 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10I43LMC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10I53LMC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10I63LMC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10I73LMC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - 09 Computer Gallons
Litres
565 N/A
G2S10I41XXC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 565 N/A
G2S10I51LMC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GG500 Transmitter Gallons
Litres
565 N/A
G2S10I52LMC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GG500 Transmitter Gallons
Litres
565 N/A
G2S10I61LMC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GX500 Transmitter Gallons
Litres
565 N/A
G2S10I62LMC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
LCD - GX500 Transmitter Gallons
Litres
565 N/A
G2S10I71XXC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 565 N/A
G2S10I72XXC 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display No Calibration 565 N/A
G2S10IXXXXA 1 in. ISO
1
in.
±1.0 % of reading with Computer
±1.5
% of reading without Computer
5 to 50 GPM
18.9 to 190
LPM
No Display Turbine Only 565 N/A
G2S15N09GMB 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 Most Popular
G2S15N19GMB 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15N43GMC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15N53GMC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15N63GMC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15N73GMC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15N41XXC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
No Display No Calibration 215 N/A
G2S15N51GMC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - GG500 Transmitter Gallons
Litres
215 N/A
G2S15N52GMC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - GG500 Transmitter Gallons
Litres
215 N/A
G2S15N61GMC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - GX500 Transmitter Gallons
Litres
215 N/A
G2S15N62GMC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - GX500 Transmitter Gallons
Litres
215 N/A
G2S15N71XXC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
No Display No Calibration 215 N/A
G2S15N72XXC 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
No Display No Calibration 215 N/A
G2S15NXXXXB 1 ½ in. NPT
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
No Display Turbine Only 215 N/A
G2S15I09LMB 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15I19LMB 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15I43LMC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15I53LMC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15I63LMC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15I73LMC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - 09 Computer Gallons
Litres
215 N/A
G2S15I41XXC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
No Display No Calibration 215 N/A
G2S15I51LMC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - GG500 Transmitter Gallons
Litres
215 N/A
G2S15I52LMC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - GG500 Transmitter Gallons
Litres
215 N/A
G2S15I61LMC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - GX500 Transmitter Gallons
Litres
215 N/A
G2S15I62LMC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
LCD - GX500 Transmitter Gallons
Litres
215 N/A
G2S15I71XXC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
No Display No Calibration 215 N/A
G2S15I72XXC 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
No Display No Calibration 215 N/A
G2S15IXXXXB 1 ½ in. ISO
1 ½
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
10 to 100 GPM
38.0 to 380
LPM
No Display Turbine Only 215 N/A
G2S20N09GMB 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 Most Popular
G2S20N19GMB 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20N43GMC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20N53GMC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20N63GMC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20N73GMC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20N41XXC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
No Display No Calibration 100 N/A
G2S20N51GMC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - GG500 Transmitter Gallons
Litres
100 N/A
G2S20N52GMC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - GG500 Transmitter Gallons
Litres
100 N/A
G2S20N61GMC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - GX500 Transmitter Gallons
Litres
100 N/A
G2S20N62GMC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - GX500 Transmitter Gallons
Litres
100 N/A
G2S20N71XXC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
No Display No Calibration 100 N/A
G2S20N72XXC 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
No Display No Calibration 100 N/A
G2S20NXXXXB 2 in. NPT
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
No Display Turbine Only 100 N/A
G2S20I09LMB 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20I19LMB 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20I43LMC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20I53LMC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20I63LMC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20I73LMC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - 09 Computer Gallons
Litres
100 N/A
G2S20I41XXC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
No Display No Calibration 100 N/A
G2S20I51LMC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - GG500 Transmitter Gallons
Litres
100 N/A
G2S20I52LMC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - GG500 Transmitter Gallons
Litres
100 N/A
G2S20I61LMC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - GX500 Transmitter Gallons
Litres
100 N/A
G2S20I62LMC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
LCD - GX500 Transmitter Gallons
Litres
100 N/A
G2S20I71XXC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
No Display No Calibration 100 N/A
G2S20I72XXC 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
No Display No Calibration 100 N/A
G2S20IXXXXB 2 in. ISO
2
in.
±0.75 % of reading with Computer
±1.0
% of reading without Computer
20 to 200 GPM
76 to 760
LPM
No Display Turbine Only 100 N/A
  Results 1 - 140 of 140 1